Accelerator card monitoring 49
LED 1 glows or flashes green or yellow.
LED 2 glows or flashes green or red.
Table 10: Accelerator card LED states
Server state LED 1 LED 2 Description
Off Off
PCIe 12 V power is not present.
Off Steady red
Configuration Programmable Logic
Device (CPLD) detected power failure
or CPLD is not configured.
Off Flashing red (1
on, 1 off)
Field Programmable Gate Array
(FPGA) configuration error detected
or configuration failed.
Off Steady green
FPGA configuration is complete.
Power up
Off Flashing red
(2 on, 2 off)
Firmware is not responding to health
check.
Flashing yellow
Steady green
Power-on self test (POST) is
executing.
Steady yellow
Steady red
POST failed.
POST
Steady green Steady green
Normal operation (passed POST).
State save
Steady yellow
Flashing green
NVRAM state save is in progress.
State restore
Flashing yellow
Flashing green
NVRAM state restore is in progress.
Upgrade
Flashing green Flashing green
Firmware upgrade is in progress.
HostCtrl
Flashing yellow
Flashing red
Not in service. Contact Customer
Support for a replacement.
Accelerator card not detected
If the server is unable to detect or communicate with an Accelerator card after you power on the server or
perform a server firmware upgrade, you see error conditions.