Page #57 background imageLoading...
Page #57 background image
Is the I/O module fault LED amber?
Possible SolutionsPossible ReasonsAnswer
No action required.Functioning properly.No
Make sure that the I/O module
is seated properly by pressing
the I/O module firmly into its
bay after the handle has clicked
in place.
CAUTION:
Never remove an I/O
module from the chassis
while the status LED is
green. Removing an
active I/O module can
result in data loss.
Contact an authorized service
provider for assistance.
The I/O module is locked.
The I/O module has failed.
Other fault condition exists.
Yes
Is the fan LED amber?
ActionsPossible ReasonsAnswers
No action requiredFunctioning properly.No
Be sure that the fan is undam-
aged and is fully seated.
Contact an authorized service
provider for assistance.
Fan might not be inserted properly,
might have a damaged connector,
or might have failed.
Yes
D2600/D2700 Disk Enclosure User Guide 57

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks D2600 and is the answer not in the manual?

HP StorageWorks D2600 Specifications

General IconGeneral
InterfaceSAS
Host Interface6 Gb/s SAS
Redundant Power SuppliesYes
Hot Plug DrivesYes
Product TypeDisk Enclosure
Supported Drive TypeSAS, SATA
Rack Height2U
CoolingRedundant fans
Drive Bays12
RAID SupportDepends on the controller
Compatible ControllersHP Smart Array P411, P812
Power SupplyTwo hot-plug, redundant power supplies
Weight48 lb (21.8 kg) (without drives)