Action(s)Error Message and DescriptionError Code
System action: Proceeds to the next
definition statement (Termination code 08).
User action: Check CODE statement and
the code to customize, and then re-execute.
The code to customize (code) does not
match with the parameter of CODE
statement.
The code to customize specified does not
match the code specified by CODE (e.g.,
double-byte code was specified as the
code to customize while EBCDIC was
specified for CODE).
CCNV10N-I
System action: Proceeds to the next
definition statement (Termination code 08).
User action: Modify the definition statement
to fit within 120 columns, and then
re-execute.
Line is longer than the maximum length.
This line will be ignored.
There is a line of definition statement over
120 columns.
CCNV10O-I
System action: Proceeds to the next
definition statement (Termination code 08).
User action: Review the definition statement
in the line with the error, and then
re-execute.
Unrecognizable definition exists in line
line_no. The unrecognizable definition will
be ignored.
Unrecognizable character string is found
in the definition statement indicated in the
line of error message.
CCNV10P-I
System action: Terminates operation
(Termination code 12).
User action: Check the output directory,
and then re-execute.
Failed to output characters for code
conversion table.
File open failed when outputting characters
for the code conversion table.
CCNV10Q-I
Character output for code conversion table
succeeded.
Character output for the code conversion
table completed successfully.
CCNV10S-I
System action: Terminates operation
(Termination code 12).
User action: Check the preceding error
message to determine the cause of the
error, and then re-execute
Cannot output characters for code
conversion table due to error encountered.
A critical error was encountered during
operation.
CCNV10T-I
System action: Terminates operation
(Termination code 0).
Standard code conversion table generated
successfully.
The standard code conversion table output
completed successfully.
CCNV10U-I
System action: Terminates operation
(Termination code 12).
User action: Check the preceding error
message to determine the cause of the
error, and then re-execute.
Cannot output standard code conversion
table due to error encountered.
A critical error was encountered during
operation.
CCNV10V-I
System action: Terminates operation
(Termination code 0).
Code conversion table information output
succeeded.
CCNV10W-I
P9000 Data Exchange Code Converter User Guide 83