ActionMeaningError messageError Code
Check the Edit Option file.
Double-byte code
conversion in the Edit
Option file contains an
incorrect code conversion
option.
Edit option file : Wrong
code conversion option in
the 2 byte code conversion
-674
Check the Edit Option file.
Double-byte code
conversion in the Edit
Option file contains an
incorrect
single-byte/double-byte.
Edit option file : Data
string type kind error in the
2 byte code conversion
-675
Confirm the FCU
configuration is correct.
Wrong parameter in
double-byte or single-byte
code conversion.
Code conversion :
Parameter error
-676
Check the Edit Option file
directory.
Double-byte or single-byte
code conversion error in
Copen (pre-processing)
operation.
Code conversion : NOT
COpen error
-677
Check the code conversion
table.
Conversion table does not
exist for double-byte or
single-byte code
conversion.
Code conversion : Cannot
find exchange table error
-678
Confirm the FCU
configuration is correct.
Conversion routine interface
error occurred in
double-byte or single-byte
code conversion.
Code conversion :
Interface area error
-679
Check the code conversion
table.
Conversion table is wrong
in double-byte or single-byte
code conversion.
Code conversion : Invalid
exchange table error
-680
Select Error from the Help
menu to view the system
error code, and then check
the operating system
document for error details.
Cannot allocate space to
read conversion table for
double-byte or single-byte
code conversion.
Code conversion : Cannot
get area for exchange table
error
-681
Select Error from the Help
menu to view the system
error code, and then check
the operating system
document for error details.
Conversion table read error
occurred in double-byte or
single-byte code
conversion.
Code conversion :
Exchange table read error
-682
Select Error from the Help
menu to view the system
error code, and then check
the operating system
document for error details.
Conversion table I/O error
occurred in double-byte or
single-byte code
conversion.
Code conversion :
Exchange table I/O error
-683
P9000 Data Exchange Code Converter User Guide 89

Table of Contents

Other manuals for HP StorageWorks P9000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks P9000 and is the answer not in the manual?

HP StorageWorks P9000 Specifications

General IconGeneral
BrandHP
ModelStorageWorks P9000
CategoryStorage
LanguageEnglish

Related product manuals