28 HP StorageWorks XP10000 Disk Array Owner’s Guide
3 MESSAGE LED
(Amber)
During normal operation, this LED should be off.
On: A service information message (SIM) has
been issued from either storage cluster. If the disk
array is set up to “phone home” to STC, your HP
support representative is notified automatically.
If the disk array is not set up to phone home,
place a service call to HP to have the message
evaluated to determine if any action is required.
Blinking: An SVP failure has occurred. The disk
array will continue to operate normally. Place a
service call to HP to ensure notification. SVP
failures might not be reported automatically to
STC.
4 RESTART Switch If a blocked path occurs between a host and a
disk drive, this switch is used to unfence the
fenced drive path and to release Write Inhibit.
During normal operation, this switch should be in
the upper position.
Restarting the array performs a soft reset to try to
recover. If the system restart does not unblock the
path, an HP support representative will be
notified.
Caution: Do not change the switch position
unless directed to do so by HP service personnel.
Table 3. Control panel functions (continued)
Item Label Indicator Description