EasyManuals Logo

HP XP1024 System Configuration

HP XP1024
69 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #38 background imageLoading...
Page #38 background image
Setting the I/O timeout parameter
Set the I/O timeout value for each disk device to 30 seconds.
To change the I/O timeout parameter:
1. V erify the current I/O time-out value using the pvdisplay command:
Example
# pvdisplay /dev/dsk/c0t6d0
- - - Physical volumes---
PV Name /dev/dsk/c0t6d0
VG Name /dev/v
g06
PV Status available
Allocatable yes
VGDA 2
Cur LV 1
PE Size (Mbytes) 4
Total PE 586
Free PE 0
Allocated PE 586 [OPEN-9]
Stale PE 0
IO Timeout
(Seconds) default
[I/O timeo
ut value]
2. If the I/O tim
eout value is not 30, change the value to 30 using the pvchange
-t command:
Example
# pvchange -t 30 /dev/dsk/c0t6d0
Physica
l volume "/dev/dsk/c0t6d0" has been successfully changed.
Volume Group configuration for /dev/vg06 has been saved in
/etc/l
vmconf/vg06.conf.
38