Questions and Answers

  • R
    Robert BeckerSep 12, 2025
    What to do if the host does not reboot properly after a hard shutdown on HP Disk array system?
    • D
      Douglas SandersSep 12, 2025
      If the host is powered off without executing the shutdown process, wait three minutes. This allows the disk array’s internal timeout process to purge queued commands. If the host restarts while the disk array is processing queued commands, it may not reboot successfully.
  • L
    Laura OconnorAug 25, 2025
    What to do if HP XP1024 host does not reboot properly after hard shutdown?
    • C
      Christopher WilsonAug 25, 2025
      If your HP Storage host doesn't reboot properly after a hard shutdown, wait three minutes after powering off the host without executing the shutdown process. This allows the disk array’s internal timeout process to purge queued commands. If the host restarts while the disk array is processing these commands, it may not reboot successfully.
  • A
    April AllenAug 25, 2025
    What to do if HP XP1024 Storage host detects a parity error?
    • D
      Derrick WilsonAug 26, 2025
      If the host detects a parity error with HP Storage, check the HBA to ensure it was installed properly. Then, reboot the host.
  • T
    Tracy FowlerSep 23, 2025
    Why does HP Disk array system self reboot?
    • W
      Wesley KnightSep 23, 2025
      If the HP Disk array system performs a self-reboot because it was busy or logged a panic message, reboot the host.
  • W
    Wendy HamiltonSep 12, 2025
    What to do if the host detects a parity error in HP Disk array system?
    • D
      dawnleeSep 12, 2025
      If the host detects a parity error, check the HBA to ensure it was installed properly. Then, reboot the host.
  • D
    Douglas JohnsonSep 17, 2025
    What to do if HP Disk array system performs a self reboot because the disk array was busy or it logged a panic message?
    • M
      mooresandraSep 17, 2025
      If the disk array performs a self reboot because it was busy or logged a panic message, reboot the host.
  • B
    Brenda RodriguezSep 5, 2025
    Why are my logical devices not recognized by the host on HP Storage?
    • R
      Ryan ShermanSep 5, 2025
      If the logical devices are not recognized by the host, verify the following: * The READY indicator lights on the disk array are ON. * Fiber cables are correctly installed and firmly connected. * The target IDs are properly configured. * The LUNs for each TID must start at 0 and continue sequentially without skipping any numbers. * The TIDs/WWNs on each bus are unique. * Do not install two devices with the same ID on the same bus. * Recheck the buses for new devices. * LUSE devices are not intermixed with normal LUNs on the same port. * The maximum number of LUSE devices per port has not been exceeded. * The disk array Host Mode is set correctly.
  • L
    Lawrence CooperSep 5, 2025
    What to do if the host does not reboot properly after hard shutdown on HP XP1024?
    • M
      Matthew RichSep 5, 2025
      If the host does not reboot properly after a hard shutdown: * If you power off the host without executing the shutdown process, wait three minutes to allow the disk array's internal timeout process to purge queued commands. * If the host restarts while the disk array is processing queued commands, the host may not reboot successfully.
  • N
    Nicole OsborneSep 18, 2025
    Why does the host hang when devices are declared on HP Disk array system?
    • J
      Jacqueline CampbellSep 18, 2025
      If your HP Disk array system's host hangs or devices are declared and the host hangs, ensure there are no duplicate disk array TIDs and that disk array TIDs do not conflict with any host TIDs.
  • C
    chamberstylerAug 30, 2025
    Why logical volumes cannot be created on HP XP1024 Storage?
    • A
      allisonseanAug 30, 2025
      If logical volumes cannot be created on your HP Storage, verify the following: * The volume capacity for OPEN-x volumes is not greater than the maximum capacity allowed (see the Emulation specifications table). * The capacity of the volume group is not less than the total capacity of the partitioned logical volume.