Why does HP XP1024 disk array perform a self reboot?
- CchristianwrightAug 31, 2025
If the HP Storage disk array performs a self-reboot because it was busy or logged a panic message, reboot the host.

Why does HP XP1024 disk array perform a self reboot?
If the HP Storage disk array performs a self-reboot because it was busy or logged a panic message, reboot the host.
What to do if HP XP1024 host does not reboot properly after hard shutdown?
If your HP Storage host doesn't reboot properly after a hard shutdown, wait three minutes after powering off the host without executing the shutdown process. This allows the disk array’s internal timeout process to purge queued commands. If the host restarts while the disk array is processing these commands, it may not reboot successfully.
What to do if HP XP1024 Storage host detects a parity error?
If the host detects a parity error with HP Storage, check the HBA to ensure it was installed properly. Then, reboot the host.
What to do if a file system is not mounted after rebooting HP XP1024 Storage?
If a file system is not mounted after rebooting HP Storage, verify that the host was restarted correctly and that the file system attributes are correct.
Why does my HP XP1024 host hang or declare devices and then hang?
If your HP Storage host hangs, or declares devices and then hangs, ensure there are no duplicate disk array Target IDs (TIDs), and that disk array TIDs do not conflict with any host TIDs.
What to do if HP Storage logical devices are not recognized by the host?
If your HP Storage logical devices are not recognized by the host, take the following steps: * Verify that the READY indicator lights on the disk array are ON. * Verify that fiber cables are correctly installed and firmly connected. * Verify that the target IDs are properly configured. The LUNs for each TID must start at 0 and continue sequentially without skipping any numbers. * Verify that the TIDs/WWNs on each bus are unique. Do not install two devices with the same ID on the same bus. Recheck the buses for new devices. * Verify that LUSE devices are not intermixed with normal LUNs on the same port. * Verify that the maximum number of LUSE devices per port has not been exceeded. * Verify that the disk array host mode is set correctly.
What to do if the HP Storage host does not reboot properly after hard shutdown?
If the HP Storage host does not reboot properly after a hard shutdown, wait three minutes to allow the disk array's internal timeout process to purge queued commands. If the host restarts while the disk array is processing queued commands, it may not reboot successfully.
What to do if the host detects a parity error on HP XP1024 Storage?
If the host detects a parity error on your HP Storage, check the Host Bus Adapter (HBA) to ensure it was installed properly. You may also need to reboot the host.
Why physical volumes cannot be created on HP Storage?
If physical volumes cannot be created on your HP Storage, verify that the disk array logical devices are correctly formatted.
Why logical volumes cannot be created on HP XP1024 Storage?
If logical volumes cannot be created on your HP Storage, verify the following: * The volume capacity for OPEN-x volumes is not greater than the maximum capacity allowed (see the Emulation specifications table). * The capacity of the volume group is not less than the total capacity of the partitioned logical volume.