EasyManua.ls Logo

HPE ProLiant DL160 Gen10 - Page 9

HPE ProLiant DL160 Gen10
134 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Item Description Status
1 UID button/LED Solid blue = Activated
Flashing blue:
1 flash per second = Remote management or firmware
upgrade in progress
4 flashes per second = iLO manual reboot sequence initiated
8 flashes per second = iLO manual reboot sequence in
progress
O = Deactivated
2
NIC status LED Solid green = Link to network
Flashing green (1 flash per second) = Network active
O = No network activity
3 Health LED Solid green = Normal
Flashing green (1 flash per second) = iLO is rebooting
Flashing amber = System degraded
Flashing red (1 flash per second) = System critical
If the health LED indicates a degraded or critical state, review
the system IML or use iLO to review the system health status.
4 Power On/Standby button and system
power LED
Solid green = System on
Flashing green (1 flash per second) = Performing power on
sequence
Solid amber = System in standby O = No power present
If the system power LED is o, verify the following conditions:
The facility power is present.
The power supply is installed and is working correctly.
The power cord is attached and is connected to a power
source.
The front I/O cable is connected.
When all four LEDs described in this table flash simultaneously, a power fault has occurred. For more information, see
Power fault LEDs on page 11.