Connecting to three drive enclosures
Figure 24: Three drive enclosure cabling configuration
1. Array enclosure 3. Drive enclosure 2
2. Drive enclosure 1 4. Drive enclosure 3
1. Connect DP-1 on the storage controller in slot 1 to DP-1 on the I/O module in slot 1 of the first drive
enclosure.
2. Connect DP-2 on the I/O module in slot 1 of the first drive enclosure to DP-1 on the I/O module in slot
1 of the second drive enclosure.
3. Connect DP-2 on the I/O module in slot 1 of the second drive enclosure to DP-1 on the I/O module in
slot 1 of the third drive enclosure.
4. Connect DP-1 on the storage controller in slot 2 to DP-1 on the I/O module in slot 2 of the third drive
enclosure.
5. Connect DP-2 on the I/O module in slot 2 of the third drive enclosure to DP-1 on the I/O module in slot
2 of the second drive enclosure.
6. Connect DP-2 on the I/O module in slot 2 of the second drive enclosure to DP-1 on the I/O module in
slot 2 of the first drive enclosure.
Multipathing with iSCSI configurations
• Access the SVMC to configure StoreVirtual networking. See the StoreVirtual Management Console
Online Help for more information.
Each controller has a pair of physical network interfaces that are bonded together.
• Two IP addresses are assigned to the bond for optimal performance.
• A total of four or eight IP addresses can be defined depending upon the number of ports.
38 Multipathing with iSCSI configurations