86
phenomena cause measure remark
ignition system
,no spark
1.switch lock
carve out a way or short
circuit,connection badness
line bonding badness
2.CDI set
After electrify no
noise from the CDI
3.high voltage
high voltage lead
insulated badness
high voltage lead carve
out a way or short circuit
4. magneto
 signal loop and charge
loop
carve out a way or short
circuit
repair
repair
replace
repalce
repalce
repalce
2. spark
weak or
sparkover
intermittence
1. spark plug
 pollute or wear
intermittence
2. high voltage bag
high voltage lead wire
insulated badness
repalce
replace
electrification
system
1,discharge self
2, uncharge or
shortage-charge
1. cover polluted or
drenched by rain
1.carve out a way or short
circuit, caused by
connected wire badness
2.rectifier damaged
3.baterry
lower-electrolyte
electrode failure
water-proof,keep
clean of the
cover and repalce
electrolyte
repair
repalce
entered
distilled water
replace
1. flash not
bright or weak
, horn sound
un
p
ro
p
erl
y
1. the switch of flash lamp
or emergency light
contacted badness
2. lamp
filament of lamp
damaged
 the watt of lamp larger
or smaller than regulated
number
3.routing
 lead wire carve out a
way or short circuit
1. horn
repair or
replace
replace
replace
repair or