EasyManua.ls Logo

HTP phoenix plus PHP260-119 - User Manual

HTP phoenix plus PHP260-119
45 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Phoenix Plus
Water Heater
Installation
Start-Up
Maintenance
Parts
Warranty
PHP Models*
* “LP” Denotes Propane Gas Operation
This manual must only be used by a qualied installer / service technician. Read all instructions in this manual before installing.
Perform steps in the given order. Failure to do so could result in substantial property damage, severe personal injury, or death.
HTP reserves the right to make product changes or updates without notice and will not be held liable for typographical errors
in literature.
NOTE TO CONSUMER: PLEASE KEEP ALL INSTRUCTIONS FOR FUTURE REFERENCE.
272 Duchaine Blvd. New Bedford, MA 02745 www.htproducts.com
LP-454 Rev. 004 Rel. 002 Date 12.1.17
The surfaces of these products contacted by potable (consumable) water contain less than 0.25% lead by weight as required
by the Safe Drinking Water Act, Section 1417.
Improper installation, adjustment, alteration, service, or maintenance could void product warranty and cause property
damage, severe personal injury, or death.
California Proposition 65 Warning: This product contains chemicals known to the State of California to cause cancer, birth
defects, or other reproductive harm.
This Manual For Use With Water Heaters Manufactured After
April 10, 2017

Table of Contents

Questions and Answers

  • M
    melindaruizSep 13, 2025
    How do I troubleshoot error code F13 on my HTP phoenix plus PHP260-119?
    • S
      Sharon HuynhSep 13, 2025
      To troubleshoot the F13 error code on your HTP Water Heater: * Check the blower wiring. * If the wiring is intact, replace the blower. * If the problem persists, replace the control board.
  • R
    Ryan HansenSep 15, 2025
    How do I troubleshoot error code E14 on my HTP phoenix plus PHP260-119 Water Heater?
    • D
      Denise JacobsonSep 15, 2025
      To troubleshoot the E14 error code on your HTP Water Heater: * Check the blower wiring, ensuring all wires are plugged in and undamaged. * If the wiring is intact, replace the blower. * If the problem persists, replace the control board.
  • A
    Alexandra CooperNov 26, 2025
    How to fix the LOU error on HTP phoenix plus PHP260-119 Water Heater?
    • T
      tstevensonNov 26, 2025
      To address the LOU error on your HTP Water Heater, first check the line voltage, ensuring it's between 100-128 volts. If available, connect a PC and use HTP service software to check the 24V supply display; the number should be greater than 128 and ideally greater than 250. Next, remove the 10-pin Molex connector from the customer connection board. If the LOU code clears, examine external sensor wiring for shorts to ground and repair. If the LOU code persists, and the heater is equipped, disconnect the high gas pressure switch, then the low gas pressure switch, then the UL 353 low water cutoff, one at a time, to see if the LOU code clears. Replace any faulty part. Check the low voltage wire harness for shorts to ground. If LOU only occurs when the burner tries to light, check the gas valve...