AP7052DN&AP7152DN
Hardware Installation and Maintenance Guide
2 AP Installation
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Cable ties are bound neatly facing the same direction, and those at the same horizontal
line must be in a straight line. Cable tie tails should be cut smoothly and evenly.
Labels or nameplates must be attached to the cables after they are installed.
Connecting Network Cables
Table 2-5 Network cable types supported by Ethernet interfaces and maximum transmission
distances
Interface Rate
Network Cable Type
Maximum Transmission
Distance
GE
CAT5e or higher
100 m
2.5GE
CAT5e or higher unshielded
twisted pair (UTP)
100 m
CAT5e or higher shielded
twisted pair (STP)
200 m
When the transmission
distance is greater than 100
m, this network cable can
only be used to connect the
following switches:
S6720-52X-PWH-SI-AC
F
S6720-52X-PWH-SI
S6720-56C-PWH-SI-AC
S6720-56C-PWH-SI
S6320-32C-PWH-SI
S6720-32C-SI-AC
S6720-32C-SI-DC
S6720-32C-PWH-SI-AC
S6720-32C-PWH-SI
5GE
CAT5e UTP
100 m (Only the first 30
m of cables is bundled in
6-a-1 mode.)
55 m (All cables are
bundled.)
100 m (Each cable is
bundled separately.)
CAT5e STP
100 m
CAT6 or higher
100 m
6-a-1 stands for the six-around-one cable bundle mode, with one cable in the center and six cables