Huawei BBU3900 - Monitoring Signal Cable between the APMI and the BBU; Table 4-10 Labels and Recommended Connections for the Branch Cables of the Multi-Mode Optical Cable between; Table 4-11 Labels and Recommended Connections for the Branch Cables of the Multi-Mode Optical Cable between; Table 4-12 Labels and Recommended Connections for the Branch Cables of the Single-Mode Optical Cable and

Huawei BBU3900
104 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 4-10 Labels and recommended connections for the branch cables of the multi-mode
optical cable between the BBU and RRU
Label Color Installation Position
1A Orange CPRI RX port on the RRU
1B Gray CPRI TX port on the RRU
2A Orange TX port on the BBU
2B Gray RX port on the BBU
Table 4-11 Labels and recommended connections for the branch cables of the multi-mode
optical cable between RRUs
Label Color Installation Position
1A Orange CPRI RX port on the RRU 1
1B Gray CPRI TX port on the RRU 1
2A Orange CPRI TX port on the RRU 0
2B Gray CPRI RX port on the RRU 0
Table 4-12 Labels and recommended connections for the branch cables of the single-mode
optical cable and recommended connections
Label
Color Installation Position
1A Yellow RX port on the BBU or CPRI RX port
on the RRU
1B Blue TX port on the BBU or CPRI TX port on
the RRU
2A Yellow ODF
2B Blue ODF
4.11 Monitoring Signal Cable Between the APMI and the
BBU
This describes the monitoring signal cable between the APMI and the BBU. It transmits the
environment monitoring signals of the power cabinet to the BBU.
BBU3900
Hardware Description 4 BBU3900 Cables
Issue 11 (2010-11-10) Huawei Proprietary and Confidential