Parameter Name Description
Communication
disconnection fail-safe
In the SUN2000 anti-backfeeding
scenario, if this parameter is set to
Enable, the SUN2000 will derate
according to the active power
derating percentage when the
communication between the
SUN2000 and the Smart Dongle is
disconnected for a period longer than
Communication disconnection
detection time.
Communication
disconnection
detection time
Species the time for determining the
communication disconnection
between the SUN2000 and the
Dongle.
This parameter is displayed when
Communication disconnection fail-
safe is set to Enable.
----End
7.2.1.2 Battery Control
Prerequisites
The screenshots in this chapter are taken in the SUN2000 3.2.00.011 app. The app
is being updated. The actual screens may vary.
Function
When the inverter connects to a battery, add the battery and set battery
parameters.
Adding a Battery
To add a battery, choose Maintenance > Subdevice management on the home
screen.
Figure 7-12 Adding a battery
Copy-SUN2000-(2KTL-6KTL)-L1
User Manual 7 Man-Machine Interaction
Issue 06 (2022-03-10) Copyright © Huawei Technologies Co., Ltd. 71