Applicable Model Application Scenario
Single inverter + Smart Dongle (WLAN-FE) + LUNA2000
connected to the management system
Parameter Settings
On the home screen, choose Power adjustment > Capacity control and set
capacity control parameters.
NO TE
The capacity control function is unavailable when the energy storage working mode is
set to Fully fed to grid.
When capacity control has been enabled, you must
rst disable capacity control and
then set the energy storage working mode to Fully fed to grid.
Figure 7-14 Setting capacity control parameters
Parameter Description Range
Capacity control 1. Before enabling Capacity
control, set Charge from
grid to Enable.
2. Before disabling Charge
from grid, set Capacity
control to Disable.
Disable
Active capacity limit
SUN2000-(2KTL-6KTL)-L1
User Manual 7 Man-Machine Interaction
Issue 10 (2023-02-13) Copyright © Huawei Technologies Co., Ltd. 82