If the MGMT port on the active MM910 is already connected with a network cable,
do not remove the network cable from the MGMT port. Otherwise, an active/standby
switchover of the MM910s will be triggered, which may cause network interruption.
If you want to connect your local PC directly to the MM910 using a network cable
but the MGMT port on the active MM910 is already connected with a network cable,
connect the network cable from the local PC to the STACK port of the active
MM910 in the chassis. If the STACK port on the active MM910 is also used, connect
the network cable to an idle STACK port on an active MM910 in a chassis cascaded
with the E9000 chassis.
6. Use an SSH connection tool to log in to the MM910 CLI by using the floating IP address
of the MM910s.
This topic describes how to use PuTTY to log in over SSH. For details, see 6.2 Logging
In to the MM910 CLI Over a Network Port by Using PuTTY.
7. Query the version of the MM910.
smmget -l smm -d version
The information is displayed as follows:
SMM Version Information:
Uboot Version :(U54)012
CPLD Version :(U1082)008 121120
PCB Version :SMMA REV B
BOM Version : 003
FPGA Version :(U1049)007 121116
Software Version :(U54)2.0
IPMI Module Built:Mar 14 2013 22:31:44
The value of the parameter Software Version is the software version of the MM910.
8. Select an operation based on the MM910 software version.
If the software version is earlier than (U54) 3.00, go to Step 4.9 to Step 4.11.
If the software version is (U54) 3.00 or later, perform Step 4.10 to Step 4.11.
9. Use a cross-platform file transfer tool, and enter the floating IP address of the MM910 to
download the configuration file to the PC in binary file transmission mode.
For operation details, see E9000 Server V100R001 Upgrade Guide.
10. Run the following command on the MM910 CLI to export the configuration file of the
converged switching plane.
root@SMM:/# swiconfexport swiN
N: specifies the slot number of a switch module. Its value ranges from 1 to 4, mapping to
switch module slots 1E, 2X, 3X, and 4E respectively.
The following information is displayed with the configuration file name and directory.
Succeed
Please check "/tmp/exchang/swiN/swiN.tar.gz"
11. Use a cross-platform file transfer tool, and enter the MM910 floating IP address to
download the configuration file shown in the command output to the PC in binary file
transmission mode.
This topic uses WinSCP as the cross-platform file transfer tool. For details, see 6.6
Transferring Files Using WinSCP.
CX320 Switch Module
User Guide
4 Configuring the CX320
Issue 09 (2019-08-02) Copyright © Huawei Technologies Co., Ltd. 77