Figure A-1 Requirements for OT/DT terminals
Crimping an OT or DT Terminal
NO TICE
Avoid scratching the core wire when stripping a cable.
The cavity formed after the conductor crimp strip of the OT or DT terminal has
been crimped must completely wrap around the core wires. In addition, the
core wires must be in close contact with the OT or DT terminal.
Wrap the wire crimping area with heat-shrink tubing or insulation tape. Heat-
shrink tubing is used in this section as an example.
Take care when using a heat gun to avoid heat damage to the equipment.