Figure 2-8 CPRI optical cable
(1) DLC connector (2) Label on the fiber tail
(3) Fiber tail
Pin Assignment
Table 2-7 describes the pin assignment for the fiber tails of the CPRI optical cable.
Table 2-7 Pin assignment for the fiber tails of the CPRI optical cable
Label Color Connect to...
1A Orange RX port on the RRU
1B Gray TX port on the RRU
2A Orange TX port on the WBBPa
2B Gray RX port on the WBBPa
 
Installation Position
Table 2-8 describes the installation positions of the CPRI optical cable.
Table 2-8 Installation positions of the CPRI optical cable
One End
The Other End
CPRI port on the WBBPa CPRI_W port on the RRU
 
2.3.4 AISG Multi-Wire Cable of the RRU/SRXU
The five-meter-long AISG multi-wire cable connects the RRU/SRXU to the Remote Control
Unit (RCU). If both RRU and SRXU are installed, the AISG multi-wire cable only connects the
SRXU and the RCU. This cable is optional.
Appearance
The cable has a waterproof DB9 connector at one end and a standard AISG female connector at
the other end, as shown in Figure 2-9.
RRU
User Guide 2 RRU and SRXU Hardware
Issue 01 (2008-04-18) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
2-13