a tower or placed on the ground. It is recommended that only one RRU be installed on angle
steel.
Prerequisite
Before you install an RRU on a tower, the RRU and mounting kits are hoisted onto the tower.
For details, see 6.6 Hoisting the RRU and Mounting Kits onto a Tower.
The hoist clamp on the main mounting bracket is secured properly.
Context
Figure 6-28 shows the top view of the RRU installed on angle steel.
Figure 6-28 Top view of the RRU
(1) Angle steel
Procedure
Step 1 Determine a position for installing the main mounting bracket.
l If the RRU must be installed on a tower, see 3.5.1 Installation Clearance for a Single
RRU to determine a position.
l If the RRU must be installed on the ground, see Figure 6-29 to determine a position.
Figure 6-29 Distance between the main mounting bracket and the ground
RRU3232
Installation Guide 6 Installing the RRU