Page #16 background imageLoading...
Page #16 background image
SUN2000-4.95KTL-JPL0
User Manual
2 Product Overview
Copyright © Huawei Technologies Co., Ltd.
10
Category
Status
Description
Blinking green
slowly (on for 1s
and then off for
1s)
Blinking green
slowly (on for 1s
and then off for
1s)
Both DC and AC are on, and
the solar inverter is not
connected to the power grid.
Off
Off
The DC is off.
Steady red
Steady red
Fault
Communication
indication
LED3
N/A
Blinking green fast (on for 0.2s and
then off for 0.2s)
Communicating
Off
No communication
2.3 Label Description
Enclosure Labels
Table 2-3 Enclosure label description
Label
Name
Meaning
Delayed discharge
Residual voltage exists
after the solar inverter is
powered off. It takes 5
minutes for the solar
inverter to discharge to
the safe voltage.
Burn warning
Do not touch a running
solar inverter because the
shell is hot when the solar
inverter is running.
Electric shock warning
High voltage exists after
the solar inverter is
powered on. Only
qualified and trained
electrical technicians are
allowed to perform
operations on the solar
inverter.
Refer to documentation
Reminds operators to
refer to the documents
shipped with the solar
inverter.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SUN 2000 Series and is the answer not in the manual?

Huawei SUN 2000 Series Specifications

General IconGeneral
TypeString Inverter
TopologyTransformerless
Cooling MethodNatural convection
Rated Output Power3-10 kW
MPPT2
CommunicationRS485
Output Power3-10 kW
Output Voltage230 V
Output Frequency50 Hz / 60 Hz
MPPT Trackers2
Operating Temperature-25 °C ~ +60 °C