9
Installing the Signal Cable
4.6
• When laying out a signal cable, separate it from the power cable to avoid signal interference.
• Cut off extra wires from the signal cable to be flush with the protection layer. Ensure that the
exposed core wire is completely inserted into the cable hole and connected securely.
EMERGENCY STOP switch signal
input
Can connect to the signal port on
the emergency stop switch (NC).
Can connect to the battery enable
signal port and RS485 signal port.
, RS485 differential signal+
, RS485 differential signal–
, RS485 differential signal+
Can connect to the RS485 signal
port on the energy meter.
, RS485 differential signal–