What to do if Huawei Inverter shows AFCI Check Failure?
- AAlexis DelacruzAug 30, 2025
If your Huawei Inverter displays an AFCI Check Failure, turn off the AC output switch and DC input switch, and then turn them on after 5 minutes.

What to do if Huawei Inverter shows AFCI Check Failure?
If your Huawei Inverter displays an AFCI Check Failure, turn off the AC output switch and DC input switch, and then turn them on after 5 minutes.
What causes a DC Arc Fault in a Huawei SUN2000-5KTL-L1 Inverter?
A DC Arc Fault in your Huawei Inverter can be caused by arcing or poor contact in the PV string power cables. Check whether the string cables arc or are in poor contact.
What to do if my Huawei SUN2000-5KTL-L1 Inverter shows Low Insulation Resistance?
If your Huawei Inverter shows a Low Insulation Resistance error, it indicates a short circuit between the PV array and the ground, or that the ambient air of the PV array is damp, causing poor insulation. First, check the output impedance of the PV array to ground. If there is a short circuit or lack of insulation, rectify it. Second, check that the PE cable of the SUN2000 is correctly connected. Third, if the impedance is lower than the specified protection threshold in rainy and cloudy days, set Insulation resistance protection using the mobile app, SmartLogger, or NMS.
What does Grid Underfrequency mean for Huawei Inverter?
If your Huawei Inverter shows a 'Grid Underfrequency' error, the power grid frequency is too low. Here's how to address it: 1. If the alarm occurs occasionally, the power grid may be temporarily abnormal. The SUN2000 will automatically recover when the grid returns to normal. 2. If it happens frequently, check if the grid frequency is within the allowed range. If not, contact your local power operator. If it is, modify the grid underfrequency protection threshold via the mobile app, SmartLogger, or NMS with the power operator's consent.
How to fix String Reversed error on Huawei SUN2000-5KTL-L1?
If your Huawei SUN2000 Inverter shows a String Reversed error, it means the PV string is reversely connected. To resolve this, check if the PV string is reversely connected to the SUN2000. If it is, wait until the PV string current decreases below 0.5 A, set the DC switch to OFF, and adjust the PV string polarity.
What to do if my Huawei SUN2000-5KTL-L1 has a Device Fault?
If your Huawei SUN2000 Inverter has a Device Fault, turn off the AC output switch and DC input switch, and then turn them on after 5 minutes.
How to cool down my Huawei SUN2000-5KTL-L1?
If your Huawei Inverter is overheating, it's likely installed in a poorly ventilated area, the ambient temperature is too high, or the device isn't working correctly. Check the ventilation and ambient temperature around the installation location.
How to fix Upgrade Failed on Huawei SUN2000-5KTL-L1 Inverter?
If the Huawei Inverter displays 'Upgrade Failed or Version Mismatch', it means the upgrade did not complete normally. Try performing the upgrade again. If it fails multiple times, contact your dealer or Huawei technical support.
What to do if my Huawei Inverter showing Overtemperature?
If your Huawei Inverter is showing an Overtemperature warning, it indicates that the unit is installed in a location with poor ventilation, the ambient temperature is too high, or the SUN2000 is not working properly. You should check the ventilation and ambient temperature of the SUN2000 installation position. If the ventilation is poor or the ambient temperature exceeds the upper threshold, improve the ventilation and heat dissipation.
What to do if Huawei SUN2000-5KTL-L1 Inverter displays DC Arc Fault?
If your Huawei Inverter displays a DC Arc Fault, it means the PV string power cables are arcing or have poor contact. You should check whether the string cables arc or are in poor contact.
| Model | SUN2000-5KTL-L1 |
|---|---|
| Max. Efficiency | 98.4% |
| Rated AC Output Power | 5000 W |
| Operating Temperature Range | -25°C to +60°C |
| Topology | Transformerless |
| Max. apparent AC power | 5500 VA |
| Max. input voltage | 600 V |
| Number of MPPT trackers | 2 |
| Max. short-circuit current per MPPT | 15 A |
| Protection degree | IP65 |
| Max. Input Power | 7500 W |
| Output Frequency | 50 Hz / 60 Hz |
| Cooling Method | Natural Convection |
| Nominal AC voltage | 230 V |
| AC voltage range | 180 V - 280 V |
| Rated Output Voltage | 230 V |
Provides critical precautions for ensuring personal safety during operations.
Outlines essential safety guidelines related to electrical hazards and connections.
Safety precautions to be followed before making electrical connections.
Guide for connecting the AC output power cable with necessary precautions.
Procedure for connecting DC input power cables, including polarity checks.
Checklist for verifying installation before powering on the system.
Prerequisites and procedure for powering on the SUN2000 system.
Guide on downloading and using the FusionSolar App for setup.
Procedure for safely powering off the SUN2000 for maintenance.
Identifies common alarms, causes, and troubleshooting steps.
Detailed technical specifications for various SUN2000 models.