3 Storage Requirements
The following requirements shall be met if inverters are not put into use
immediately:
Do not unpack inverters.
Keep the storage temperature at –40°C to +70°C and the humidity at 5%–
95% RH.
Store inverters in a clean and dry place and protect them from dust and
moisture.
Inverters can be stacked in a maximum of eight layers. To avoid personal
injury or device damage, stack inverters with caution to prevent them from
falling over.
During the storage period, check inverters periodically (recommended: once
every three months). Replace the packing materials that are damaged by
insects or rodents in a timely manner.
If inverters have been stored for two years or longer, they must be checked
and tested by professionals before being put into use.