Huawei Proprietary and Confidential                                     
Copyright © Huawei Technologies Co., Ltd. 
 
g.  Disconnect the PGND cables. 
For details, see Follow-up Procedure in 5.1 Connecting PGND Cables. 
----End 
8.2 Routine Maintenance 
To ensure that the SUN2000 can operate properly for a long term, you are advised to perform 
routine maintenance on it as described in this chapter. 
 
 
 
Before cleaning the system, and maintaining the cable connections and grounding 
reliability, power off the system (see 8.1 Powering Off the SUN2000) and ensure that the 
DC SWITCH on the inverter is OFF. 
 
Before wiping the heat sink clean, switch off the circuit breaker between the SUN2000 and 
the power grid, set the DC SWITCH to OFF, and wait at least 5 minutes after the 
SUN2000 is powered off. 
Table 8-1 Maintenance list 
Check periodically that the heat sinks are free from 
obstacles or dust. 
Semiannually to 
annually. 
 
Check that the SUN2000 is not damaged or 
deformed. 
 
Check for normal sound emitted during operation 
of the SUN2000. 
 
Check that all SUN2000 parameter settings are 
correctly set during operation. 
 
Check that cables are securely connected. 
 
Check that cables are intact and the parts in 
contact with a metallic surface are not scratched. 
 
Check that the idle RS485 and USB ports are 
covered by waterproof caps. 
Half a year after the 
initial commissioning, 
and semiannually to 
annually afterwards. 
Check that PGND cables are securely connected. 
Half a year after the 
initial commissioning, 
and semiannually to 
annually afterwards.