LED Indicator Status Remarks Description
Blinking red
and green
alternately
Blinking slowly
(on for 1s and
o for 1s)
No communication with the
inverter:
Remove and then insert
the Smart Dongle.
Check whether the
inverter matches the
Smart Dongle.
Connect the Smart
Dongle to another
inverter.
Check whether the
Smart Dongle is faulty or
the USB port of the
inverter is faulty.
----End
SUN2000-(12KTL-25KTL)-M5 Series
User Manual 6 Commissioning
Issue 03 (2023-02-15) Copyright © Huawei Digital Power Technologies Co., Ltd. 52

Table of Contents

Other manuals for Huawei SUN2000 M5 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SUN2000 M5 Series and is the answer not in the manual?

Huawei SUN2000 M5 Series Specifications

General IconGeneral
Max Efficiency98.6%
Max Input Voltage1100 V
MPPT Operating Voltage Range200 V - 1000 V
Operating Temperature Range-25°C to +60°C
CommunicationRS485, 4G (optional)