SR05-D1A3-PV manual v1801 78/83
MODBUS REGISTERS 0x10000x1052, continued
REGISTER
ADDRESS
(HEX)
PARAMETER DESCRIPTION OF CONTENT TYPE
OF
(R/W)
FORMAT
OF DATA
0x1028 Sensor serial number R U16
0x1029 +
0x102A
Sensor sensitivity
In x 10
-6
V/(W/m
2
)
R
Float
0x102B Response time In x 0.1 s R U16
0x102C
Sensor resistance
In x 0.1
R
U16
0x102D Reserved Always 0 R U16
0x102E +
0x102F
Sensor calibration date
Calibration date of the sensor
in YYYYMMDD
R
U32
0x1030 to
0x103C
Factory use
0x103D Firmware version R U16
0x103E Hardware version R U16
0x103F +
0x1040
Sensor sensitivity
history 1
In x 10
-6
V/(W/m
2
)
Default value is 0
R Float
0x1041 +
0x1042
Calibration date history
1
Former calibration date of the
sensor in YYYYMMDD
Default value is 0
R U32
0x1043 +
0x1044
Sensor sensitivity
history 2
See register 0x103F +
0x1040
R Float
0x1045 +
0x1046
Calibration date history
2
See register 0x1041 +
0x1042
R
U32
0x1047 +
0x1048
Sensor sensitivity
history 3
See register 0x103F +
0x1040
R Float
0x1049 +
0x104A
Calibration date history
3
See register 0x1041 +
0x1042
R
U32
0x104B +
0x104C
Sensor sensitivity
history 4
See register 0x103F +
0x1040
R Float
0x104D +
0x104E
Calibration date history
4
See register 0x1041 +
0x1042
R
U32
0x104F +
0x1050
Sensor sensitivity
history 5
See register 0x103F +
0x1040
R Float
0x1051 +
0x1052
Calibration date history
5
See register 0x1041 +
0x1042
R U32
Note 1: Up to five 16 bit registers can be requested in one request. If requesting six