10
Switch Test
1. Connect electrical power cord to AC power source and air supply line to the air inlet (if necessary).
2. Turn the DSP9600/9100 Balancer “ON” while holding the Right and Left Split Weight buttons during power up
to enter “Diagnostic Mode.” Press the “Next” button to begin showing diagnostic variables.
3. Dial the “D” knob to diagnostic item number 36. Zero will be displayed on the right digits.
4. Press all buttons and close all switches. Each switch closure should be followed by a beep indicating that the
switch is functioning.
5. Dial the “D” knob clockwise to exit the switch test.
Verify Installation of Auto Dataset Arm(s) (DSP9600 only):
1. While in “Diagnostic Mode,” press “Next” to verify that the wire connection for the Inner and optional Outer
Dataset® Arms are correct:
a.) Dial the “D” knob to diagnostic item number 28. Move the Outer Dataset® Arm in a horizontal
line from right to left. The real-time numbers displayed on channel 28 on the screen should
increase.
b.) Dial the “D” knob to diagnostic item number 26. Move the Inner Dataset® Arm in a horizontal
line from left to right. The real-time numbers displayed on channel 26 on the screen should
decrease.
c.) Dial the “D” knob to diagnostic item number 27. Move the Inner Dataset® Arm in a vertical
line upward. The real-time numbers displayed on channel 27 on the screen should increase.
d.) If the numbers are not behaving as described above, the cable connections are reversed and
need to be exchanged.
2. Calibrate Auto Inner and Outer Dataset® Arms.
Auto Inner Dataset® Arm (DSP9600 only):
NOTE: Requires Calibration Tool, 221-672-1
1. Press “Setup/Cal” button once. “CAL” is displayed.
2. Press
“Next” button. “CAL” is displayed at inner Dataset® arm location, and “---]” is displayed if
equipped with outer Dataset® arm.