12
g.) Place the inner Dataset® arm at downward position “4.” Tap the foot pedal once or press
“Enter.”
1
2
3
h.) Move the inner Dataset® arm to downward position “5.” Tap the foot pedal once or press
“Enter.”
i.) Move the inner Dataset® arm to downward position “6.” Tap the foot pedal once or press
“Enter.”
j.) Position the calibration tool parallel to the spindle shaft on the hub using the hub
mounting slot as shown.
9
8
7
k.) Place the inner Dataset® arm at the position “7.” Tap the foot pedal once or press
“Enter.”
l.) Move the inner Dataset® arm to position “8.” Tap the foot pedal once or press “Enter.”
m.) Move the inner Dataset® arm to position “9.” Tap the foot pedal once or press “Enter.”
If optional auto outer Dataset® arm is not installed, calibration is complete. If optional auto outer Dataset® arm is
installed, continue with Auto Outer Dataset® Arm Calibration.