10
TECHNICAL INFORMATION
Default Settings
• None pre programmed. With a non-volatile memory, a default setting is not necessary.
Electrical Specications
• Transformer input: 115VAC, 60Hz/230-240VAC, 50Hz
• Transformer output: 24VAC, 1.5A (40VA)
• Station Output: 24VAC, 0.56A
• Master Valve output: 24VAC, 0.28A
• Maximum total output: 24VAC, 1.4A (up to two zone valves per station output plus master
valve or pump start relay)
• Program Backup: Non-volatile memory, battery programmable
Dimensions
Operating Specications
• Station Run Time:
0 to 1 hour and 59 minutes in 1 minute
increments for programs A, B, C; 0 to 12
hours in 1 minute increments in program
D; global seasonal adjust from 10-150%
in 10% increments.
• Start Times:
Eight start times per program, program-
mable delay between stations, program-
mable master valve circuit.
• Programs:
A, B, C programs have independent day
cycles, will stack start times, program D
will run concurrently with all programs.
Built-in test program, 2 minutes each
station.
Programmable delay between stations
of up to 10 hours.
• Watering Schedule:
Four schedule options–any day on or off
with 7 day calendar; any day on or off
with 31 day calendar; odd day program-
ming; or even day programming with 365
day, leap year intelligent calendar.
• Cycle/Soak:
Cycle can be programmed for up to 60
minutes; Soak can be programmed for up
to 60 minutes.
• Rain Delay:
1 to 7 day delay can be programmed
to temporarily interrupt the watering
schedule.
Plastic Cabinet Metal or Stainless Metal or Stainless Plastic Pedestal
Steel Cabinet Steel Pedestal
• Height: 11" (28 cm) • Height: 15" (40 cm) • Height: 30" (76 cm) • Height: 38" (97 cm)
• Width: 12" (30.5 cm) • Width: 11
3
/
8
" (29 cm) • Width: 11
3
/
8
" (29 cm) • Width: 21" (55 cm)
• Depth: 3" (9.5 cm) • Depth: 4" (11.4 cm) • Depth: 4" (10 cm) • Depth: 15" (40 cm)