ICC Controller
4. Press the days remaining in the Interval
are now ashing. Press and to select the
number of days until the next desired watering.
One day remaining means it will water the
next day.
Automatic Operation
After programming, set dial to RUN to enable
automatic operation of all scheduled waterings.
Rain Sensor Bypass Switch
If a sensor is preventing system operation
(or no sensor is installed and the switch is in
the ON position), SEN OFF will be displayed.
Move the switch to OFF and the rain sensor
will be bypassed.
Seasonal Adjust
Press and to change the seasonal adjust
from 10% to 150% in 10% increments. The
station run times displayed will automatically
be recalculated.
System Off
Turn dial to the SYSTEM OFF position. Shuts
down all programmed waterings indenitely
until the dial is returned to the RUN position.
Can be used to cancel waterings in progress.
Programmable Rain Off
This feature permits the user to stop all
programmed waterings for a designated
period from 1-7 days. At the end of the rain
delay, the controller will resume normal
automatic operation.
1. Move the rotary switch to the OFF position.
2. Press the button and a 1 will be displayed
and the DAYS icon will illuminate.
3. Press as many times as needed to set the
desired number of days off, up to 7 days.
4. Turn the dial back to the RUN position.
NOTE: The days off remaining will decrease
at midnight of each day. When days off gets to
zero, the display will show the normal time of
day and normal irrigation will resume at the
next scheduled start time.
Advanced Features
This controller is capable of Cycle and Soak
watering, Master Valve / Pump programming
and also features a programmable delay
between stations. Please refer to your ownerʼs
manual for programming instructions regarding
these advanced features.
Manually Operating a Single Station
1. Turn dial to the MANUAL-SINGLE STATION
position.
2. Station run time will ash in the display. Press
to move to the desired station. Press
and to change the amount of time for valve
to water.
3. Turn the dial to the RUN position to run the
station. (Station designated will water, then
controller will return to automatic mode.)
Manually Operating All Stations
1. Turn dial to the MANUAL-ALL STATIONS
position.
2. Select program A, B, C or D, by pressing
.
3. To start on a station other than #1, press
until desired starting station is displayed.
4. Return dial to RUN (stations in designated
program will water, then controller will return
to automatic mode).
A complete copy of the ICC Programming Instructions is in
the ICC Owner’s Manual, Hunter literature number: LIT-237