EasyManua.ls Logo

Hunter PRO-C P2C Series - Specifications; Operating Specifications; Cabinet Dimensions; Electrical Specifications

Hunter PRO-C P2C Series
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3
Built on Innovation
®
Operating Specications
Station Count: Conventional wiring from 4 to 23 stations,
two-wire EZ Decoder System option up to 32 stations
Station Run Time: 1 minute to 6 hours (optional Seconds
Mode, see pg. 18)
Start Times: 4 individual starts per program, three
programs available (A, B, C)
Watering Schedule: 7-day calendar, interval watering up
to a 31-day interval or true odd or even day programming
Electrical Specications
Transformer Input: 120 VAC, 60 Hz (230 VAC, 50/60 Hz
for international use)
Transformer Output: 24 VAC, 1 A
Station Output: 24 VAC, 0.56 A per station
P/MV Output: 24 VAC, 0.28 A
Maximum Output: 24 VAC, 0.84 A (includes Master
Valve Circuit)
Battery: 9 V alkaline battery (not included) used only for
non-AC programming of the control panel
Battery, front panel, internal CR2032 lithium for real-
time clock
Specications
Cabinet Dimensions
Height: 9" (23 cm)
Width: 10" (21.5 cm)
Depth: 4" (10.9 cm)
Cabinet is NEMA 3R, IP44 rated
Default Settings
All stations are set to zero run time. This controller has a
non-volatile memory that retains all entered program data,
even during power outages, without need for a battery.

Related product manuals