The controller does not respond
to all stations. Example, the
controller has 12 stations but the
display will only go to 6 stations.
Controller does not recognize
modules.
Press "RESET" if it still does not
recognize all modules, turn off the
power to the controller and remove
the battery. Check all module
connections to the controller. Power
the controller back up. The
microprocessor will recognize all
modules.
The controller does not have a
start time for each station.
Programming error, dial in incorrect
position.
Be sure the dial is in correct position.
Total number of stations can be
easily checked by placing dial in SET
STATION RUN TIMES position and
pressing the back arrow.
The controller is continuously
watering, even when it should not
be on/ Cycling repeatedly.
Too many start times (user error).
Only one start time per active
program is required. Refer to
“Setting Watering Start Times”.
There are not enough start times
for all stations.
The controller has only four start
times per program.
Controller continues cycling over
and over.
User has set multiple start times for
a Program. Only one start time is
needed to run a complete program.