22 BLINK CODE 98
Blink code FI warning lamp (MIL)
02 FI warning lamp (MIL) flashes 2x short
Error level condition Crankshaft position sensor - circuit fault
Blink code FI warning lamp (MIL)
06 FI warning lamp (MIL) flashes 6x short
Error level condition Throttle position sensor circuit A - input signal too low
Throttle position sensor circuit A - input signal too high
Blink code FI warning lamp (MIL)
09 FI warning lamp (MIL) flashes 9x short
Error level condition Manifold absolute pressure sensor cylinder 1 - input signal too low
Manifold absolute pressure sensor cylinder 1 - input signal too high
Blink code FI warning lamp (MIL)
12 FI warning lamp (MIL) flashes 1x long, 2x short
Error level condition Engine coolant temperature sensor - input signal too low
Engine coolant temperature sensor - input signal too high
Blink code FI warning lamp (MIL)
13 FI warning lamp (MIL) flashes 1x long, 3x short
Error level condition Intake air temperature sensor - input signal too low
Intake air temperature sensor - input signal too high
Blink code FI warning lamp (MIL)
15 FI warning lamp (MIL) flashes 1x long, 5x short
Error level condition Rollover sensor (A/D type) - input signal too low
Rollover sensor (A/D type) - input signal too high
Blink code FI warning lamp (MIL)
17 FI warning lamp (MIL) flashes 1x long, 7x short
Error level condition
FE EU
Lambda sensor cylinder 1, sensor 1 - circuit fault
Blink code FI warning lamp (MIL)
33 FI warning lamp (MIL) flashes 3x long, 3x short
Error level condition Injector cylinder 1 - circuit fault
Blink code FI warning lamp (MIL)
37 FI warning lamp (MIL) flashes 3x long, 7x short
Error level condition Ignition coil 1, cylinder 1 - circuit fault
Blink code FI warning lamp (MIL)
41 FI warning lamp (MIL) flashes 4x long, 1x short
Error level condition Fuel pump control - open/short circuit to ground
Fuel pump control - input signal too low