9.18 Assembling the control unit
1
Connect the connector from the motor to the con-
trol unit. Connect connector (D) to the control unit
for the keypad, fan and main switch. Make sure the
connector is plugged firmly into the control unit.
See figure 18b.
2
Place all the control unit components in the battery
housing.
Take care to return all the cables to their correct
positions to avoid pinching.
Fastenscrews(2x)tothecontrolunit(G)and
screws (2x) to the battery contact (H).
Tightening torque 1 Nm.
See figure 19b.
3
Assemble the battery housing as described in
"7 Basic dismantle/assembly" on page 20
9.19 Changing the handle
1
Loosen the knob alternatively the wing nut by hand
and remove the parts from the shaft.
2
Assemble the new parts between the spacer and
the shaft.
See figure 33