P/N 3141959_C 5-7
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
FNGSC-A Self Contained Merchandisers
REPLACING SOLENOID VALVES
Unplug the power cords before servicing.
1. Remove product and place in a refrigerated
area. Make sure the power is off to the
case.
2. Make sure there is no voltage in the
refrigerator. Remove rear lower panel.
4. Remove condensate pan screws and
disconnect heater wires.
5. Take off the condensate pan and replace
heater.
6. Reverse the process and make sure
everything is in place.
Parts may be ordered at Hussmanns Performance
Parts e-store:
https://parts.hussmann.com/
Call toll free: 855-487-7778
or
Required Tools:
Screwdriver / Philips Tip
1/4" Allen Wrench
Copper Tubing Cutter
Blow Torch
FNGSC8A Shown
FNGSC8A Shown
FNGSC8A Shown