SECTION 4
10.1 Relay 1 = 10.1.1 Relay 1 De-Energise Switch rake off in failsafe.
10.2 Relay 2 = 10.2.2 Relay 2 De-Energise Alarm level indication on failsafe.
10.4 Fail Time = 600 Failsafe time in seconds
10.5 mA Fail = 10.5.3 Analogue Hold Analogue output holds on failsafe.
11.1 Analog O/P = 11.1.1 Output 4–20mA 4-20mA output fixed to span (Pr.3.0).
12.4 Relay tot. = 12.4.2 Relay totaliser On This counts the number of times the rake is
turned on, and how many hours it has been
energised.
NOTE:- It is not possible to simulate any differential mode applications.
Ref: MINIFLEX LR MANUAL Rev. 0 42