Electrical connection of sensor
Connection cable - Assignment / Color coding
Our accessories list on page 117 includes the required connection cables of
various lengths with one connection plug (M12x1, 8-pole, according to DIN
VDE 0627) and an open end.
HYDAC accessory cable color coding is listed in the table below:
Pin
Color
Connection to
1
White
Supply voltage 9-36 V DC
2
brown
Analog output + (active)
3
Green
GND power supply
4
Yellow
GND ANALOG / SWITCH OUTPUTS
5
grey
HSI (HYDAC Sensor Interface)
6
Pink
RS485 +
7
blue
RS485 -
8
Red
Switching output (passive, n.c.)
Housing
-
Shield