The current (I) or voltage (U) can be calculated for a given SAE
contamination class as follows:
I = 4.8 mA + SAE class x (19.2 mA - 4.8 mA) / 14
U = 2.4 V + SAE class x (9.6 V - 2.4 V) / 14
The current (I) or voltage (U) can be calculated for a given SAE
contamination class as follows:
SAE class = (I - 4.8 mA) x (14/14.4 mA)
SAE class = (U - 2.4 V) x (14/7.2 V)
ContaminationSensor CS1000
en(us)
Page 68 / 136