26
SMART WINTER MODE
Smart Winter Mode protects your system from
the cold by turning the pumps on several times a
day to prevent water from freezing in the pipes.
The Smart Winter Mode indicator turns on when in this
mode of operation.
If the temperature drops to 4°C (39°F) within the heater
chamber, the system automatically activates the pump to
provide freeze protection. The pump will operate until the
temperature reaches 5°C (41°F) before returning to nor-
mal system mode.
COOL DOWN
After heating the spa water to the desired set point, the
heater is turned off, but the filtration pump remains on for
a certain amount of time to ensure adequate cooling of the
heating element in order to prolong the useful life of the
heater. The heater icon flashes during this time.
PURGE CYCLES
The purge cycles are programmed to begin at the start of
each filter cycle. Pump 2 activates for 1 minute, shuts off
and then Pump 1 activates for 1 minute and then shuts
off.
OPTIONAL OZONATOR
The ozonator operates during FILTER CYCLES only and
remains off for 30 minutes after usage.