Hr - An internal hardware error has been detected
Prr - The Prr error message indicates a problem with the regulation probe. The system is constantly verifying if the tem
perature probe reading is within its normal limits.
HL - The water temperature at the heater has reached 119
o
F (48
o
C). Do not enter spa water.
FLO - The system did not detect any water flow while the filtration pump was running.
UPL - No low level configuration software has been downloaded into the system.
AOH - The temperature inside the spa skirt is too high, causing the internal temperature in the spa pack to increase
above the normal limits.
OH - The water temperature in the spa has reached 108
o
F (42
o
C). Do not enter spa water.
TOPSIDE PANEL DISPLAY MESSAGES
OPTIONAL VARIABLE AIR THERAPY
SYSTEM CONTROL FUNCTIONS:
Press: Blower button on main control to activate system.
1) ON/OFF :
Press 1: The Blower starts at maximum Speed. LED: ON
Press 2: The blower stops. LED: OFF
2) TO CONTROL SPEED:
Press 1 and hold: Speed goes up or down, LED: ON when pressing. Release
pressure at the desired speed.
3) TO CONTROL PULSATION:
Press 1: Slow Pulsation Cycle, LED: ON.
Press 2: Quick Pulsation Cycle, LED: Flashes.
Press 3: Pulsation Cycle OFF, LED: OFF.