Installation, Programming and Maintenance User Guide Oxymatic Smart
V. 1.3.2. May 2015
3
1. IMPORTANTSAFETYINSTRUCTIONS
PLEASE READ AND FOLLOW THESE INSTRUCTIONS
It is essential when installing a control and disinfection system at a pool to take
certain precautions whilst handling equipment, also more generally while using the
pool.
DANGER: Low-voltage electricity risk: Do not open or touch the control unit: there is
a risk of electric shocks. Contact your local retailer or the manufacturer.
Follow the electricity safety instructions laid down by your company, also local or
national regulations.
DANGER: Risk of accidents or drowning: Use of the pool calls for special care.
Observe the safety and hygiene instructions laid down, which are displayed near the
pool, or in accordance with local or national regulations.
2. ELECTRICALSPECIFICATIONSANDFEATURES
OXYMATIC® SMART complies with:
- Low-voltage regulations in accordance with ITC-BT standard 031 (2002)
- Electrical and electromagnetic safety standards in accordance with directive 7323 / ECC / EN61010-1 (93)
ELECTRICAL SPECIFICATIONS: Mod. OXYMATIC® SMART
Power supply 110/250 Vac
Operating frequency 50/60 Hz
Energy consumption when not running 120 mA
Oxidation sequence consumption at 6 amps 350 mA
Ionisation sequence consumption at 2 amps 180 mA
Operating temperature + 5° / + 55°C
Maximum operating humidity 95% with no condensation
Protection of the environment IP55
Maximal voltage at the Titanium chamber 12 VDC (with galvanic separation)
Maximum voltage at the Copper chamber 12 VDC (with galvanic separation)
OPERATING ALGORITHMS: Mod. OXYMATIC® SMART
Manual/ automatic operation? Yes
User programs? Yes
Temperature readout At 5°/55°C intervals; accurate to +/- 0,2ºC
pH readout At 5 - 50 pH intervals
ORP readout At intervals of +/- 2000 mV
Automatic pH dose corrector By peristaltic pump (setting P + I)
Automatic Rx dosing By peristaltic pump (setting P + I)
Touch-screen Colour 10"
Programming By touch-screen and password
Type of programming User-friendly and intuitive