Installation, Programming and Maintenance User Guide Oxymatic Smart
V. 1.3.2. May 2015
35
10. MAINTENANCEOFTHEOXYMATICSYSTEM
10.1. Maintenanceandcontroltable:
From now on, all you must do is maintain the equipment, checking the parameters detailed below:
PARARAMETER
RECOMMENDED DATA
INCREASE
REDUCE
CONTROL
pH
6.8 to 7.5
Add pH increaser
liquid
Add pH reducer
Liquid
Sulphuric acid (dilute
38%) (H
2
SO
4
) better than
hydrochloric dilute acid
(HCl)
Automatic pH
Regulador
Copper (ppm)
0.5 – 0.7
Increase the time of
ionization or add
copper sulphate
Dilute a portion of the
pool water and reduce the
operation time of the
Ionization.
Monthly
H
2
O
2
(ppm) 10 – 20
Hydrogen peroxide
(H2O2). Increase
minutes per day
dosing.
Decrease minutes or
renew daily dosing of the
pool water Weekly
Voltage (V) to Ti
electrodes
<
9.5 Vac
No
Increase the conductivity
of the water by
adding SALT in the water
(NaCl) Weekly
IMPORTANT: In order for the Titanium electrodes (Ti) to work 100% effectively and to avoid
deterioration, they should work at only 9.5 v, otherwise its life expectancy will be only a few
months. The GUARANTEE does not cover the deterioration of the electrodes.
The voltage should be measured weekly.
10.2. OncetheOxymaticsystemisinprogress:
If the pump circuit is turned on, the PUMP light will go on. PUMP ON
If the OXY position is on, the green light corresponding to the control unit of the OXIDATION
must go on. OXY
If it is on the ION/PER position, the corresponding green light will turn on. ION/PER
NOTE: The keys OXY and ION, have two green lights. Once every so often one of the lights
will turn off and the other one will go on This means that the change in polarity has taken
place between the electrodes.
o If the ºC / AUX light comes on, this means that the auxiliary channel is on.
o If the LIGHT light is on, this means that the LIGHT channel is on.
o If the pH/mV light is on, this means that the regulating pump is on / REDOX. If the LOW and
HEIGHT lights are on, this indicates that pH is lower thanset point 1 (7.0) or aboveset
point 2” (7.8). When the pH is below 7.0, the regulating pump of pH will inject acid.