OXYMATIC circuits transform the standard electrical current (220 V, 50 Hz) DC low voltage and
amperage. By its titanium electrodes (plated precious metals), creating ionized water, disinfectant
chemical species.
Thus, it creates a combination of the most powerful oxidizers available for water disinfection, avoiding
the use of chemicals. In the case of hydroxyl ions (oxidation-reduction potential of 2.05, exceeded only
by fluorine, but because of its high toxicity can not be used as a disinfectant).
Table 1 shows the key values of redox potential.
OXIDATION REDUCTION POTENTIAL (ORP)
Chemical name
Symbol
ORP Value
1
Fluorine F
2
2.25
2
Hydroxyl Ion
OH
-
2.05
3
Atomic Oxygen
O
-
1.78
4
Ozone O
3
1.52
5
Hydrogen Peroxide
H
2
O
2
1.30
6
Permanganate
KMn
2
O
7
1.22
7
Hypochlorous
Á
cid
HClO
1.10
8
Chlorine (Gas)
Cl
2
1.00
9
Oxygen O
2
0.94
10
Sodium Hypochlorite
NaClO
0.69
* Oxidants produced by the system OXYMATIC
3.3 IONIZATION
From the copper electrodes
OXYMATIC system generates
copper ions Cu
++
, which
effectively remove algae,
bacteria and viruses. In addition,
there is no scientific evidence
that the organisms are
developing immunity to copper
ions, contrary to what happens
with various forms of chlorine.
The recommended dosage (0.5
and 0.7 ppm) does not affect
health as according to WHO
(World Health Organization) a
potable water up to 2 mg / l of
copper.