Troubleshoot Common Problems
6
Powermax65/85/105 SYNC Operator Manual 810470 155
MFG This field shows the manufacture date of the Hypertherm cartridge in year-month-day format
(YYYY-MM-DD) followed by the manufacture identification number (.nn) and the manufacture
location code (@nn).
UID This field shows the unique identification number of the Hypertherm cartridge.
STA – This field shows the total number of pilot arc starts that the Hypertherm cartridge has done in
its life.
XFR This field shows the total number of arc transfers that the Hypertherm cartridge has done in
its life.
PT – This field shows the cumulative pilot arc time in hours, minutes, and seconds (HH:MM:SS)
that the Hypertherm cartridge has had in its life.
XT – This field shows the cumulative arc transfer time in hours, minutes, and
seconds (HH:MM:SS) that the Hypertherm cartridge has had in its life.
F0, F1, F2, F3 – These fields show the 4 most recent operational fault codes that occurred while
cutting or gouging with the cartridge. Operational fault codes are in the format 0-nn-n. Refer
to page 130.
To see these fields, scroll down to the CARTRIDGE DATA 2 screen.

Table of Contents

Other manuals for Hypertherm SYNC Powermax 85

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm SYNC Powermax 85 and is the answer not in the manual?

Hypertherm SYNC Powermax 85 Specifications

General IconGeneral
BrandHypertherm
ModelSYNC Powermax 85
CategoryWelding System
LanguageEnglish

Related product manuals