Install and Set Up the Plasma Power Supply
2
44 810470 Operator Manual Powermax65/85/105 SYNC
Powermax105 SYNC
CSA configurations (3-phase)
230 V – 400 V CE configurations (3-phase)
380 V CCC / 400 V CE configurations (3-phase)
Input voltage at 50Hz/60Hz* 200V 208V 240V 480V 600V
Input current at rated output
(105 A x 160 VDC = 16.8 kW)
58 A 56 A 49 A 25 A 22 A
Input current during arc stretch 82 A 82 A 78 A 40 A 35 A
Fuse (time-delay) 80 A 80 A 80 A 40 A 40 A
* All models have a voltage tolerance of +10% / -15%.
Input voltage at 50Hz/60Hz* 230V 400V
Input current at rated output (105 A x 160 VDC = 16.8 kW) 50 A 29 A
Input current during arc stretch 80 A 46 A
Fuse (time-delay) 80 A 50 A
* All models have a voltage tolerance of +10% / -15%.
Input voltage at 50 Hz/60 Hz* CCC 380 V CE 400 V
Input current at rated output (105 A x 160 VDC = 16.8 kW) 30 A 28 A
Input current during arc stretch 42 A 44 A
Fuse (time-delay) 50 A 50 A