EasyManua.ls Logo

Hypertherm SYNC Powermax 85 - Powermax85 SYNC Electrical Configurations; Powermax85 SYNC CSA 1-Phase Configuration; Powermax85 SYNC CSA 3-Phase Configuration; Powermax85 SYNC CE;CCC 3-Phase Configuration

Hypertherm SYNC Powermax 85
174 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Install and Set Up the Plasma Power Supply
2
Powermax65/85/105 SYNC Operator Manual 810470 43
Powermax85 SYNC
CSA configurations (1-phase)
CSA configurations (3-phase)
CE/CCC configurations (3-phase)
Input voltage at 50 Hz/60 Hz* 200 V – 208 V 230 V – 240 V 480 V
Input current at rated output (85 A × 143 VDC = 12.2 kW) 70 A / 68 A 58 A 29 A
Input current during arc stretch 98 A 98 A 50 A
Fuse (time-delay) 100 A 100 A 50 A
* All models have a voltage tolerance of +10% / -15%.
Input voltage at 50 Hz/60 Hz* 200 V – 208 V 230 V – 240 V 400 V 480 V 600 V
Input current at rated output
(85 A × 143 VDC = 12.2 kW)
42 A / 40 A 35 A 21 A 18 A 17 A
Input current during arc stretch 60 A 60 A 38 A 31 A 30 A
Fuse (time-delay) 60 A 60 A 40 A 30 A 30 A
* All models have a voltage tolerance of +10% / -15%.
Input voltage at 50 Hz/60 Hz* 380 V 400 V
Input current at rated output (85 A × 143 VDC = 12.2 kW) 20.5 A 19.5 A
Input current during arc stretch 38 A 38 A
Fuse (time-delay) 40 A 40 A
* All models have a voltage tolerance of +10% / -15%.