42 D0559 Rev. A SlideDriver/SlideDriver 50VF Series www.hysecurity.com
Table 2 describes the Installer Menu items and supplies the factory defaults. (Factory settings shown in bold.)
Installer menu: taBle 2
Installer Menu Setting Options Menu Tasks & Explanations STC Wire
Connections
OT 0
<model name>
0 = Operator Type
1 = SlideDriver (HSG) all models
except 50VF series
2 = SwingRiser (HRG)
3 = HydraLift (HVG)
4 = StrongArm (HTG)
5 = SlideWinder 24
6 = SlideWinder 38
7 = SlideDriver 50VF
8 = StrongArm CRASH
9 = HydraSwing
Select the appropriate number for the operator.
NOTE: This menu item only appears if the Smart
Touch Controller is being replaced.
CAUTION: If you are replacing an
STC board, remember to transfer the
operator’s menu settings from the
existing board to the replacement board.
Refer to the installation instructions that
accompany the replacement STC board.
Not applicable (N/A)
AD 0
AC/DC GATE
0 = gate disabled
1 = AC (alternating current)
2 = DC battery-power (OT 1-4, 7&8)
Select the type of power that the operator uses
and is appropriately wired.
NOTE: This menu item only appears when you
set the OT (operator type).
N/A
SP 0
SET SPEED
(or indicate Modbus
control)
0 = gate disabled
1 = No ModBus communication**
2 = 2 ft/s
3 = 3 ft/s
**NOTE: A setting of 1 indicates no
ModBus communication or wiring
is present. The VFD uses its factory
settings to control speed.
Set the maximum speed for the gate.
NOTE: This menu item only appears if the Slide-
Driver operator is part of the 50VF series. It does
not appear with any other operator type.
CAUTION: Standard and Stop extended
limit ramps must be installed on the drive
rails!
N/A
UC 0
USAGE CLASS
0 = gate disabled
1 = single family dwelling
2 = multi-family
3 = industrial *
4 = guarded location *
*not serving the general public
Designates the UL 325 Usage Class (UC). The
installer sets the usage class for the operator to
function.
NOTE: The usage class setting does not appear
on Crash products.
N/A
SH 0
GATE HANDING
0 = gate disabled
R = viewed from the secure side, the
gate moves right to open
L = viewed from the secure side, the
gate moves left to open
Handing only appears on slide gate operators
(OT 1, 5 – 7). On slide gates, the installer sets
the operator’s handing before the operator will
function, so an R or L appears in the display.
N/A
BU 0
LOUDEST BUZZER
0 = buzzer not set
1 = Frequency 1 * (on)
2 = Frequency 2 * (on)
*Select the loudest buzzer
This menu item only appears if the operator type
selected is 1 through 4.
Choose the loudest buzzer. The operator
provides an audible beep when you select either
buzzer 1 or 2. Make sure to choose the loudest
audible buzzer sound for your operator type.
N/A
FD 0 (OFF)
FACTORY DEFAULTS
0 = user settings (custom)
1 = reload factory settings
Select setting 1 to return the operator to factory
defaults. Globally restores all menu settings back
to new operator status.
NOTE: If factory defaults are restored, any
customized menu settings will need to be
reprogrammed. You can save your customized
menu settings using a PC laptop & S.T.A.R.T.
N/A

Table of Contents

Other manuals for HySecurity SlideDriver 50 VF Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HySecurity SlideDriver 50 VF Series and is the answer not in the manual?

HySecurity SlideDriver 50 VF Series Specifications

General IconGeneral
BrandHySecurity
ModelSlideDriver 50 VF Series
CategoryGate Opener
LanguageEnglish

Related product manuals