Table 1. Maintenance Schedule (Continued)
Item
No.
Item 8 hr/
Daily
500 hr/
3 mo
2000 hr/
1 yr
4000 hr/
2 yr
Procedure or
Quantity
Specification
11 Hydraulic Oil
Sub-zero Construction
(Total Capacity)
X C 57 liter (60 qt)
NOTE 8
-40 to 22°C
(-40 to 71.6°F)
Hydraulic Oil MIL-
H-5606A
Horn, Lights, and
Alarm
X Check operation.
Oil Leaks X Check for leaks.
Safety Labels X Replace as
necessary.
See Parts Manual.
Battery and Battery
Restraint System
X Check condition.
See NOTE 4 and
NOTE 12.
Hood Latch and
Release Handle
X, L Lubricate as
Necessary.
Check operation.
See NOTE 11.
Manual Control Lever
Release Latch
X,L Lubricate as
Necessary.
Check operation.
See NOTE 11.
Steering Column Tilt
Memory Lever
X Lubricate as
Necessary.
Check operation.
Use multipurpose
grease.
See NOTE 1.
Operator Restraint
System
X
CIL
Check condition.
Lift System Operation
Check
X Check operation.
Operator Presence
System Check
X Check operation.
20 Pivots (Mast) X L 2 fittings,
lubricate as
required.
Use multipurpose
grease.
See NOTE 1.
14 Mast Sliding Surfaces X L Lubricate as
required.
See NOTE 5.
Use multipurpose
grease.
See NOTE 1.
17 Integral Sideshift
Carriage
X L 2 fittings.
See NOTE 5.
Use multipurpose
grease.
See NOTE 1.
Header Hoses, Hose
Fittings and Clamps
X X Inspect for
kinked,
flattened, stiff, or
charred hoses.
Replace if necessary.
Hydraulic Control
Levers and Pedals
X Check operation.
Steering System X Check operation.
X=Check C=Change L=Lubricate CIL=Check Indicator Light during operation
Maintenance Schedule 8000 SRM 1541
8