RCP6 Actuator
Gripper Type
First Step Guide Second Edition
Thank you for purchasing our product.
Make sure to read the Safety Guide and detailed Instruction Manual (CD/DVD) included with the product in addition to
this First Step Guide to ensure correct use.
This Instruction Manual is original.
Using or copying all or part of this Instruction Manual without permission is prohibited.
The company names, names of products and trademarks of each company shown in the sentences are registered
trademarks.
This product is comprised of the following parts if it is of standard configuration.
If you find any fault in the contained model or any missing parts, contact us or our distributor.
1. Parts (The option is excluded.)
No. Part Name Model Quantit
y
Remarks
1
Actuator
Refer to “How to Read the Model
Nameplate” and “How to Read the Model
Number.”
1
Accessories
2 Motor encoder
cables
(Note1)
1
3 First Step Guide 1
4 Instruction Manual
(DVD)
1
5 Safety Guide 1
Note 1 Please refer to the wiring layout for the enclosed motor cable and encoder cable.
2. How to Read the Model Plate
3. How to Read the Model No.
3.1 Thin Type Gripper
Note 1 Identification for IAI use only: It may be displayed for IAI use. It is not a code to show the model type.
[Refer to the catalog or Instruction Manual (DVD) for specification details.]
3.2 Long Stroke Gripper
RCP6-GRST6C-WA-42P-2-180-P3-P-B-**
<Series>
Standard Specification <Options>
RCP6 B : With Brake
Built-in Controller Specification NM : Reversed-home Specification
RCP6S CJT : Cable Exit Direction Changed
(Top) (Top)
<Type> CJR : Cable Exit Direction Changed
Motor Straight Type (Right)
GRST6C CJL : Cable Exit Direction Changed
GRST7C (Left)
Motor Reversing Type CJB : Cable Exit Direction Changed
GRST6R (Bottom)
GRST7R CJO : Cable Exit Direction Changed
(Outward)
<Encoder Type> ML : Motor Unit Left-Reversed
WA : Battery-less Absolute Direction
MR : Motor Unit Right-Reversed
<Motor Type> Direction
42P : 42size SS : Slider Spacer
56P : 56size SR : Slider Roller Specification
MJF : Slider Attachment Installation
<Lead> Tool
2/8
<Cable Length>
<Stroke> N : None
GRST6C, GRST6R P : 1m
180 (One side 90), 230 (One side 115) S : 3m
RGST7C, GRST7R M : 5m
210 (One side 105), 260 (One side 130) X□□ : Length Specification
R□□ : Robot Cable
Standard Specification
<Applicable Controllers>
P3 : PCON-CB/CGB, PCON-CYB/PLB/POB
MCON-C/CG/LC/LCG, MSEL-PC/PG
P5 : RCON-PC
RCM-P6PC
Built-in Controller Specification
<I/O Type>
SE : SIO Type
Precautions in Handling
1. Handling the Packed Unit
Do not damage or drop. The package is not applied with any special treatment that enables it to resist
an impact caused by a drop or crash.
Transport a heavy package with at least more than two operators. Consider an appropriate method for
transportation.
Keep the unit in a horizontal orientation when placing it on the ground or transporting. Follow the
instruction if there is any for the packaging condition.
Do not step or sit on the package.
Do not put any load that may cause a deformation or breakage of the package.
2. Handling the Actuator After Unpacking
Do not carry the actuator by its motor unit or its cable or attempt to move it by pulling the
cable.
Hold the frame or motor cover section of the body when transporting the actuator main body.
Do not hit or drop the actuator during transportation.
Do not attempt to force any part of the actuator. Do not apply excess force especially on the fingers and
finger guide.
Environments for Installation, Storage and Preservation
Usage is possible in environments of pollution degree 3 or equivalent.
1. Installation Environment
The actuator should be installed in a location other than those specified below.
Also provide sufficient work space required for maintenance inspection.
Where the actuator receives radiant heat from strong heat sources such as heat treatment furnaces
Where the ambient temperature exceeds the range of 0 to 40C
Where the temperature changes rapidly and condensation occurs
Where relative humidity smaller than 20% or larger than 85%RH
Where the actuator receives direct sunlight
Where the actuator is exposed to corrosive or combustible gases
Where the ambient air contains a large amount of powder dust, salt or iron (at level exceeding what is
normally expected in an assembly plant)
Where the actuator is subject to splashed water, oil (including oil mist or cutting fluid) or chemical
solutions
Where the actuator receives impact or vibration
Place with an altitude of 2,000m or more
If the actuator is used in any of the following locations, provide sufficient shielding measures:
Where noise generates due to static electricity, etc.
Where the actuator is subject to a strong electric or magnetic field
Where the actuator is subject to ultraviolet ray or radiation
Names of the Parts
1. Thin Type Gripper GTRT7A/GRT7B
End Cover
(Cable)
Frame
End Cover (Belt)
Guide
Finger Opening and
Closing Screw
Hole Caps
Actuator Cable
Finger Opening and
Closing Screw
Fingers
[For the details of dimensions and outlines, refer to the catalog or Instruction Manual (DVD).]
2. Long Stroke Gripper GRST6C/GRST7C/GRST6R/GRST7R
2.1 Standard Specification Motor Straight Type
2.2 Built-in Controller Specification Motor Straight Type
Product Check
MODEL RCP6-GRT7A-WA-28P-1-30-P3-P-NM
SERIAL No.000090266
MADE IN JAPAN
RCP6
GRT7
A
-W
A
- 28P - 1 - 30 - P3
P
NM - * *
Series
<Type>
Slide Type
GRT7A
GRT7B
<Encoder Type>
WA : Battery-less absolute
<Motor Type>
28P : 28 size
<Gear Ratio Pattern>
GRT7A
1 : Feed screw lead length 1.5mm
Pulley deceleration ratio 1.5
GRT7B
1 : Feed screw lead length 2mm
Pulley deceleration ratio 1.25
2 : Feed screw lead length 2mm
Pulley deceleration ratio 2.5
<Stroke>
Identification for IAI use only
(Note1)
<Options>
AC1 :
Actuator cable 1m specification
AC2 :
Actuator cable 2m specification
AC3 :
Actuator cable 3m specification
NM :
Reversed-home specification
CJTB :
Rear cable ejection to top side
CJLB :
Rear cable ejection to left side
CJRB :
Rear cable ejection to right sid
e
CJBB :
Rear cable ejection to bottom
side
CJTS :
Side cable ejection to top side
CJLS :
Side cable ejection to left side
CJRS :
Side cable ejection to right side
CJBS :
Side cable ejection to bottom
side
<Cable Length>
N : None
P : 1m
S : 3m
M : 5m
X□□ : Length specification
R□□ : Robot cable
<Controller>
P3 : PCON-CB/CGB
PCON-CYB/PLB/POB
MCON-C/CG/LC/LCG
MSEL-PC/PG
P5 : RCON-PC
RCM-P6PC
Model
Serial numbe
r
Warning: Operation of this equipment requires detailed installation and operation instructions which are
provided on the CD/DVD Manual included in the box this device was packaged in. It should be
retained with this device at all times.
A hard copy of Manual can be requested by contacting your nearest IAI Sales Office listed at
the back cove
r
of the Instruction Manual or on the First Step Guide.
Identification for IAI use only
(Note 1)
2. Storage • Preservation Environment
The storage and preservation environment should comply with the same standards as those for the
installation environment. In particular, when the machine is to be stored for a long time, pay close
attention to environmental conditions so that no dew condensation forms.
Unless specially specified, moisture absorbency protection is not included in the package when the
machine is delivered. In the case that the machine is to be stored and preserved in an environment
where dew condensation is anticipated, take the condensation preventive measures from outside of
the entire package, or directly after opening the package.
For storage and preservation temperature, the machine withstands temperatures up to 60C for a
short time, but in the case of the storage and preservation period of 1 month or more, control the
temperature to 50C or less.
Storage and preservation should be performed in the horizontal condition. In the case it is stored in the
packaged condition, follow the posture instruction if any displayed on the package.
Note 1 Identification for IAI use onl
y
:
It may be displayed for IAI use. It is not a code to show the model
type.
[Refer to the catalog or Instruction Manual (DVD) for specification details.]

Other manuals for IAI RCP6 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IAI RCP6 Series and is the answer not in the manual?

IAI RCP6 Series Specifications

General IconGeneral
TypeController
ModelRCP6 Series
Storage Temperature-10 to 60°C
Control MethodPosition Control
ProgrammingIAI Software
Communication InterfaceRS-232C, Ethernet
Humidity85% RH or less (non-condensing)